Protecting Frames from Outdoor Corrosion: ISO 12944 and the Duplex System

Corrosion protection for a frame is chosen to suit the environment where the furniture will stand. First, the corrosivity category is determined according to ISO 12944-2, from C1 to CX. Then the expected protection durability is set: up to 7 years, 7–15 years, 15–25 years, or over 25 years. In gardens and city parks, powder-coated steel is often used, with chemical surface preparation and an appropriate coating thickness. By the sea, around swimming pools, in industrial areas, and wherever long durability is required, a duplex system is used. This means hot-dip galvanizing according to EN ISO 1461 and powder coating according to EN 15773.
Below we describe how to choose the right protection and what to specify when ordering frames for garden, terrace, and urban furniture. The coatings we apply are described on the page machining and special coatings.
Frame corrosion protection in brief
- Define the environment: corrosivity category C1–CX according to ISO 12944-2.
- Define the required protection durability: L, M, H, or VH according to ISO 12944-1.
- Choose the system: powder coating or hot-dip galvanizing with powder coating, i.e., a duplex system.
- Take care of the design: rounded edges, no places where water can stand, drainage of closed profiles.
- Specify the coating thickness and acceptance tests in the order: thickness and adhesion measurement.
Step 1: corrosivity categories according to ISO 12944-2
The ISO 12944-2 standard divides atmospheric environments into six categories. The same bench will behave differently in a garden outside the city than on a seaside promenade.
| Category | Corrosivity | Typical environment according to ISO 12944-2 |
|---|---|---|
| C1 | very low | heated buildings with clean air: offices, schools, hotels, stores |
| C2 | low | rural areas with low pollution; unheated buildings where condensation may occur, for example warehouses and sports halls |
| C3 | medium | urban and industrial atmosphere with moderate pollution; coastal areas with low salinity; humid production halls |
| C4 | high | industrial and coastal areas with moderate salinity; chemical plants, swimming pools |
| C5 | very high | industrial areas with high humidity and an aggressive atmosphere; coastal areas with high salinity |
| CX | extreme | offshore areas with high salinity, tropical climate with high humidity and an aggressive atmosphere |
For garden and urban furniture, this means that a bench in a park in a big city usually operates in category C3. A bench on a seaside promenade or by a swimming pool may operate in category C4 or higher.
Step 2: protection durability according to ISO 12944-1
Protection durability is the time from applying the coating to the first major renovation. It is not a warranty period.
| Durability class | Time to first major renovation |
|---|---|
| L – low | up to 7 years |
| M – medium | 7–15 years |
| H – high | 15–25 years |
| VH – very high | over 25 years |
Powder Coating of Frames
Surface preparation
The durability of a powder coating depends primarily on surface preparation. The parts are degreased and usually given a conversion layer, which forms through a chemical reaction with the metal. On steel and cast iron this is usually a phosphate layer. Galvanized steel and aluminum are prepared with chromate treatment, its chromium-free equivalents, or anodizing. Finally, the parts are thoroughly dried. For steel intended for harsher conditions, abrasive blasting is also used.
Application and Curing
The powder is applied electrostatically. In the corona method, an electrode charges the particles; in the tribo method, the charge comes from friction in the gun. The charged powder settles on the grounded part. The part then goes into an oven, where the powder melts and cross-links. The typical oven temperature range is about 150–200 °C. The required time and object temperature are given in the powder's technical data sheet, for example 10 minutes at an object temperature of 180 °C.
Powder Coating Thickness
- about 60–80 µm: decorative coatings and standard protection;
- often 80–120 µm: enhanced protection and better edge coverage;
- above 120 µm: special applications requiring suitable powders and process control.
Coating thickness on steel is measured with the magnetic method according to ISO 2178. On aluminum, the eddy current method according to ISO 2360 is used. Measurement points are set on flat surfaces, edges, and in recesses, because that is where the thickness tends to be lowest.
Coating Quality Control
Adhesion is checked with the cross-cut test according to ISO 2409. The cut spacing depends on coating thickness. On a metal substrate it is 1 mm for coatings up to 60 µm, 2 mm for 61–120 µm, and 3 mm for 121–250 µm. The result is rated on a scale from 0 to 5. Corrosion resistance is compared in a salt spray chamber according to ISO 9227. This is an accelerated, comparative test, so its result in hours cannot be directly converted into years of service life.
What to Specify When Ordering Coated Frames
- the corrosivity category and the required durability class;
- the protection system: powder coating alone or a duplex system;
- the RAL color, gloss level, and surface texture;
- the minimum coating thickness and measurement locations;
- the surface preparation method;
- acceptance tests: thickness and adhesion measurements and, for large orders, salt spray testing on samples.
Hot-Dip Galvanizing and the Duplex System
Hot-Dip Galvanizing According to EN ISO 1461
In hot-dip galvanizing, a steel part is immersed in a bath of molten zinc. The EN ISO 1461 standard specifies the minimum zinc coating thickness depending on the steel thickness.
| Steel thickness (non-centrifuged parts) | Local thickness, min. | Average thickness, min. |
|---|---|---|
| over 6 mm | 70 µm | 85 µm |
| over 3 mm up to 6 mm | 55 µm | 70 µm |
| from 1.5 mm to 3 mm | 45 µm | 55 µm |
| below 1.5 mm | 35 µm | 45 µm |
A frame made of 6 mm sheet, for example a bench frame, falls into the range of over 3 mm up to 6 mm. The average zinc thickness should be at least 70 µm.
Duplex System According to EN 15773
A duplex system combines hot-dip galvanizing with a paint coating, for example powder coating. The zinc protects the steel cathodically, while the powder coating protects the zinc and provides color. The industrial application of powder coatings on hot-dip galvanized steel is described in the EN 15773 standard. The zinc surface must be properly prepared; otherwise the powder coating may peel off or blisters may form in it.
Aluminum Outdoors
Aluminum is covered by a natural oxide layer, but outdoors it is usually powder coated anyway, for protection and color. The specifics of powder coatings on aluminum castings are described in the article outdoor powder coating from our foundry.
Frame Design and Corrosion
- Sharp edges: the powder coating is thinner on them, so it is worth rounding the edges or planning for a thicker coating.
- Closed profiles: for hot-dip galvanizing they need inlet and vent holes. Outdoors, they also must not collect water.
- Gaps and contact points with wood: they trap moisture, so it is worth separating the seat from the sheet metal with spacers or leaving a drainage path for water.
- Contact between different metals: aluminum in constant contact with stainless steel in damp conditions suffers galvanic corrosion. Insulating washers help.
- Plastic feet: they lift the ends of the legs off wet surfaces.
- Fasteners: outdoors, stainless or galvanized screws are used, as we explain in our guide to attaching the tabletop and seat to the frame.
Guide to choosing protection for where the furniture will be placed
| Location | Typical category | Commonly used solution |
|---|---|---|
| Heated interiors: offices, hotels, restaurants | C1 | powder coating |
| Covered terrace, shelter, rural area | C2 | powder coating with chemical surface pretreatment |
| Garden, park, urban housing estate | C3 | powder coating with increased thickness; duplex system when long service life is required |
| Coastline, swimming pools, industrial areas | C4–C5 | duplex system |
The table is indicative. The protection system is chosen for the specific location, the required durability and the powder manufacturer's technical data.
Frames for outdoor benches and tables
Our metal bench frames 1100 and 1600 are powder coated, and the coating protects them from moisture and corrosion. We describe the dimensions of benches for gardens and urban spaces in the article bench dimensions. We discuss the EN 581 series of standards for outdoor furniture in the article standards for contract furniture.
Coating care
Even a good coating needs care. Road salt and deposits from sea air are best washed off with clean water. Damage to the coating must be repaired quickly, before corrosion creeps under the paint. You will find more tips in the article how to care for metal frames. We compare powder coating with galvanic coatings in the text powder coating vs. galvanizing.
Frequently asked questions
Is powder coating enough for outdoor use?
It depends on the corrosivity category and the required durability. In gardens and city parks, meaning category C3, powder coating with good surface preparation is often used. By the sea and around swimming pools, a duplex system is used.
What is a duplex system?
It combines hot-dip galvanizing according to EN ISO 1461 with a paint coating, for example powder coating. Applying powder to galvanized steel is described in the EN 15773 standard.
What should the thickness of a powder coating be?
About 60–80 µm for standard protection, and often 80–120 µm when enhanced protection and better edge coverage are needed.
How can the quality of powder coating be checked?
Coating thickness is measured (on steel according to ISO 2178, on aluminum according to ISO 2360), and adhesion is tested with the cross-cut method according to ISO 2409. Corrosion resistance is compared in a salt spray chamber according to ISO 9227.
How many years will the coating last outdoors?
ISO 12944-1 describes durability classes from L (up to 7 years) to VH (over 25 years). This is the time to the first major renovation in a given corrosivity category, not a warranty.
Does a salt spray test result tell you how many years the coating will last?
No. The ISO 9227 test is accelerated and comparative. It allows you to compare coating systems, but it cannot be directly converted into years.
Sources
- From C1–C5 and CX: corrosivity categories (ISO 12944-2) (VIOX)
- ISO 12944 standard and corrosion protection (Tikkurila): durability classes
- EN ISO 1461 – minimum zinc coating thicknesses (Galvanizers Association)
- EN 15773 – powder coatings on galvanized steel (duplex systems) (CEN)
- Powder coating: temperature and film thickness (FreiLacke)
- What is powder coating? (Kluthe)
- ISO 2409 – cross-cut adhesion test (Rotlex)
Prepared by: ADT Components (Adjatech Metalworking, Janikowo near Poznań). Status: November 2026.